RoPump DN 600 Domestic Pumping Station
#PumpingStation
#WastewaterTechnology
#Drainage
#Infrastructure
#CivilEngineering
#WaterTechnology
#PEShaft
RoPump DN 600 – Domestic Pumping Station for Reliable Wastewater Conveyance
The RoPump DN 600 is a compact and powerful domestic pumping station designed for the safe conveyance of wastewater across elevation differences.
It is deployed wherever natural gradients are insufficient and wastewater must be reliably lifted and transported onward. Thanks to its sophisticated design and robust construction, it is suitable for use in both private and commercial settings.
Typical Applications:
- Single-family and multi-family homes
- Drainage of basements, basement apartments, or buildings situated below the backflow level
- Commercial and industrial properties
- Wastewater conveyance in production halls, workshops, or storage areas with lower-lying drainage points
- Sanitary facilities located below the sewer level
- Toilets, showers, or washrooms that cannot be drained via gravity flow
RoPump DN 600 in detail.
At the heart of the system stands a robust polyethylene (PE) shaft, specifically engineered to meet the demands of underground installation as well as ongoing operation. The material is corrosion-resistant, durable, and capable of withstanding both mechanical stresses during installation and the continuous loads encountered during operation. Its compact design, featuring a nominal diameter (DN) of 600, enables space-saving integration while ensuring high performance.



Scope of Delivery:
• DN 600 Shaft
• Submersible Pump
• Two Float Switches
• Check Valve, Shut-off Valve, and Discharge Pipe
• Feka VS with Lifting Device
The control unit and cover are not included in the scope of delivery. For control units and additional options, please refer to the accessories section.
Operation: When the wastewater level in the pump sump reaches a specific height, the pump is switched on. The switching on and off of the pump must be controlled by a level switch or a corresponding sensor. The size of the pump sump—as well as the level at which the pump is to be activated—is determined by the inflow volume, the pump’s capacity, or the maximum number of switching cycles per hour. The discharge line must be equipped with a check valve to prevent water from flowing back from the discharge line into the pump sump. A shut-off valve on the discharge line must be closed in the event of a pump failure.
Technica Data and Dimensions
Advantages
The RoPump DN 600 domestic pumping station offers a wide range of advantages. Here is an overview:
Economic Viability & Efficiency
- Automatic operation via level switch → demand-based switching (on/off), reduced energy costs.
- Optimized pump cycles based on inflow volume → reduced wear, longer service life
- Compact DN 600 design → minimal space requirements and rapid installation
- Pre-configured system (pump, valves, pressure line) → reduced on-site assembly time
Safety & Structural Analysis
- Polyethylene shaft → high resistance to mechanical loads during installation and operation
- Check valve prevents backflow → Protection against flooding of the pump sump.
- Shut-off valve for maintenance and fault situations → enables safe shutdown
- Integrated Manhole → Safe Access for Inspection and Service
- Designed for defined switching cycles → reliable operation even with fluctuating inflow.
Sustainability & Maintenance
- Durable PE material → corrosion-free and low-maintenance
- Efficient submersible pump → reduced operating costs over its service life
- Lifting Device (Feka VS) → Fast and easy maintenance without complex disassembly
- Modularly expandable (control system optional) → adaptable to project-specific requirements
Accesories
The following accessories are available:
Code | Description |
|---|---|
7200088830 | Control Unit for Pumping Station SMART EVO 1 (for one 230 V pump) |
1290087 | SMART EVO 1 Pump Station Controller
(for one 230 V pump with GSM module) |
720008840 | SMART EVO 2 Pump Station Controller (for 2 pumps, 230 V) |
1290088 | SMART EVO 2 Pump Station Controller
(for 2 pumps, 230 V, and GSM module) |
1290089 | Control Unit for Pump Station SMART EVO 2 3F 7.5 kW |
1290090 | Control Unit for Pump Station EXPRESS D2-MONO |
Code | Description |
|---|---|
R000285 | Coarse Solids Separator for Pumping Station DN600 |
R000278 | Coarse Solids Separator for Pump Station DN800 |
R000417 | Coarse Solids Separator for Pump Station DN1200 |
R000400 | Stainless Steel Guide for Coarse Material Separator DN600 |
R000401 | Stainless Steel Guide for Coarse Material Separator DN800 |
Code | Description |
|---|---|
R000386 | Guide for Coarse Solids Separator DN600 | Height: 725 mm |
R000387 | Guide for Coarse Solids Separator DN600 | Height: 1025 mm |
R000388 | Guide for Coarse Solids Separator DN800 | Height: 725 mm |
R000389 | Guide for Coarse Solids Separator DN800 | Height: 1025 mm |
R000416 | Guide for Coarse Solids Separator DN1200 | Height: 1077 mm |
Code | Description |
|---|---|
7200088310 | Outdoor Pedestal P4 (455 x 235 x 1350 mm) |
7200088890 | Outdoor Column P4.5 (402 x 300 x 1280 mm) |
7200088670 | Outdoor Column P5 (625 x 420 x 1400 mm) |
7700000020 | Access Shaft Extension for RoPump DN600 (600 x 750 mm) |
7106548710 | Access Shaft Extension for RoPump DN800 (800 x 750 mm) |
7106548720 | Dome Extension for RoPump DN1000 (1000 x 750 mm) |
Installation
Installing the RoPump is simple due to its shape and light weight. You can find more detailed information in the installation instructions.
Other RoPump Variants
RoPump DN 600
Compact pumping station with one pump and a 600 mm shaft – ideal for smaller applications.
selected
RoPump DN 800
Dual-pump system with 800 mm shaft – for higher flow rates and increased safety.
More about the product
RoPump DN 1200
High-performance solution with two pumps and a 1,200 mm shaft—for high wastewater volumes.
FAQ
For compensating for differences in elevation and conveying wastewater in drainage systems.
Via level switches or sensors that automatically switch the pump on and off.
No, the control unit and cover are optional accessories.
Check valve to prevent backflow, and shut-off valve for maintenance or malfunctions.