Our RoOxy complete systems are delivered as a one-tank, two-chamber system of 4-8 residents.
Thanks to the integrated, rotated partition wall, the container has excellent static properties. Due to the narrow rectangular shape, easy installation is possible even in cramped installation conditions. The two telescopic manholes DN 600 ensure optimal accessibility for maintenance and service work.
We can implement larger systems individually as a multi-tank version up to a connection size of 50 PU.
RoOxy advantages
- Sewage-resistant system made of PE
- Pre-assembled ready to plug in
- External column as standard: ready to plug in with control, air distributor and compressor
- No putrefaction processes resulting in fewer odours
- No electrically operated or rotating components in the waste water
- Drainage class C as standard
- Drainage class D possible
Dimensions of the RoOxy sewage treatment plant
Code | Name | Volume [L] | Length [mm] | Width [mm] | Height [mm] | Weight [kg] | 7200070500 | RoOxy 4 PU | 4000 | 2450 | 1350 | 1750-2050 | 300 |
---|---|---|---|---|---|---|
7200070510 | RoOxy 6 PU | 5200 | 2450 | 1350 | 2000-2300 | 330 |
7200070520 | RoOxy 8 PU | 6000 | 2450 | 1350 | 2520-2720 | 365 |
Scope of delivery
- EcoBox container with 2 telescopic dome shafts DN 600 (walkable)
- pre-assembled SBR technology RoOxy
- PE outdoor column, ready to plug in, with controller, air distributor with solenoid valve for sludge return and compressor
Attention:
The air supply lines are not included in the scope of delivery. 4 hoses DN 13 are required.
Benefits
- SBR systems with electric pumps and float switches
- SBR plants with air lift
- SBR systems with submersible motor aerator and dosing via backwash sludge pump
- fluidized bed and fixed bed systems
- Dripping filters in a wide variety of designs
The control can be operated via 3 buttons or via Wi-Fi and an integrated web browser.
Dial-up possible via a router, no GSM module required.
Outputs
- 5 relays 230V
- 1 relay 16A nominal, socket CEE 7/3 in the left wall of the housing
- 2 relays 16A nominal via clamp (PE, N and L in different colors)
- 2 relays 5A nominal value via terminal (PE, N and L in different colors)
- Max. 4 relays can be switched simultaneously
- 1 output for alarm lamp (5V DC, 20mA max.)
Technical specifications
- graphic LCD 128x64 pixels, 2.4”, backlit
- 3x LED (error-red; operation-yellow; eco-green)
- 3 button operation
Inputs
- 2 digital inputs via terminals
- 1 analog 4-20mA input (external power supply)
- 230V mains connection 1 m with CEE 7/7 (=”Schuko”) plug
- USB connection for data transfer to the control unit
- Pressure sensor for water level measurement and fan monitoring, 0-500mbar
Other
- Common current monitoring for all outputs (max. 3A)
- Fusing 6.3A common for all outputs
- Easily replaceable NiMH rechargeable batteries for power failure alarm and signaling (2 x AA)
- Buzzer for audible alarms including power failure
- RTC (Time & Date), battery backed up
- Wi-Fi module